Beijing Global Dowin Technology CO.,LTD
Place of Origin: | China |
Brand Name: | oem |
Certification: | CE, FDA |
Model Number: | oem |
Minimum Order Quantity: | Negotiable |
---|---|
Price: | Negotiable |
Packaging Details: | Standard Carton Box or Wooden Case |
Delivery Time: | 7 days |
Payment Terms: | T/T, L/C |
Supply Ability: | Enough stock |
Name: | Medial Infrared Forehead Thermometer | Display: | LCD Digital Display |
---|---|---|---|
Measure Time: | About 1-2 Seconds | Accuracy: | High |
Application: | Business Residential Areas | OEM/ODM: | Available |
Certification: | CE, FDA | Instrument Classification: | Class II |
High Precision Non Contact Infrared Thermometer For Body Temperature Measuring
Characteristic
1. Single-point laser aiming.
2. Intelligent USB power supply.
3. Secondary white backlight display (the meter will automatically turn on this function when USB is connected).
4. Current temperature plus MIN (minimum), MAX (maximum), DIF (temperature difference), AVG (average) temperature
display.
5. Emissivity is adjustable.
6. Trigger is locked.
7. Celsius / Fahrenheit selection.
8. Tripod installation.
9. One 9V battery.
Introduction
The infrared thermometer used to measure the temperature of the human body is called the human infrared
thermometer. But it must be clarified that there is no special medical or industrial infrared thermometer, because
the manufacturing principles of infrared thermometers are the same. There are only high precision, high distance
coefficient ratio, high performance infrared thermometers and low precision, low distance coefficient ratio and low
performance infrared thermometers. As long as the emissivity of the infrared thermometer is set to 0.95 (the
emissivity of human skin is generally this value, even if there is a difference, the impact is only within 0.3
degrees), it is in line with the requirements of human body temperature measurement.
Note
A warning describes actions that may cause a hazardous situation to the user. To avoid electric shock or personal
injury, follow these guidelines:
Do not aim the laser directly at your eyes or indirectly reflected surfaces. Before using the thermometer, check
the case. If the thermometer is damaged, do not use it. Look for damage or missing plastic parts. Replace the
battery as soon as the battery indicator "" appears. Do not use the thermometer if it is malfunctioning. Instrument
protection may have been compromised. If in doubt, send the thermometer for repair. Do not use the thermometer near
explosive gases, vapors or dust. To avoid the risk of burns, keep in mind that objects with high reflectivity will
often make temperature measurements lower than the actual temperature of the object. If this equipment is used in a
manner not specified in this manual, the protection provided by the equipment may be impaired.
To avoid damaging the thermometer or device under test, protect them from the following injuries:
From EMF (electromagnetic field) including electric welding machines, electric induction heaters, static
electricity, thermal shock (caused by large or sudden ambient temperature changes-wait 30 minutes to stabilize the
thermometer before use). Do not leave the thermometer on or near hot objects. Various symbols and safety signs on
the thermometer and in the manual.
Contact Person: Lily
Medial Grade Non Contact Forehead Infrared Thermometer With Back Light Display
Portable Medical Infrared Thermometer , Non Contact Forehead Thermometer
High Precision Non Contact Infrared Thermometer For Body Temperature Measuring
Medical Grade Ear Thermometer , High Accuracy Infrared Clinical Thermometer
Digital Infrared Ear Thermometer With LCD Digital Display CE FDA Approval
Professional IR Ear Thermometer , Telemetry Digital Infrared Thermometer
Safety Digital Body Thermometer , Portable Digital Thermometer For Human Body
High Accuracy Digital Clinical Thermometer For Oral / Rectal / Axillary
Small Size Most Accurate Digital Thermometer With Last Memory Reading